top of page

Solar Panel I-V Curve
To see all our tests please download our document located in the document section
​
Test 4: To characterize the I-V curve of our 25 Watt solar panel
Goal: To determine load required for max power
Parts used: 25 watt solar cell, 100 watt potentiometer 500 ohm, Fluke 115 multimeter
Image to the right shows the setup used for this test.
​
Following image shows the testing environment. Note: the leaves were not an issue with direct sunlight. Temperature was 70 F, and humidity was 55%.
​
​
​
​
Table below shows the resulting I-V curve based on different loads. The maximum power is achieved at around 20 ohms, which gave us the load resistance for our maximum power circuit.
​
​
​
​
​
​
​
​



bottom of page